How to read and decode Ducane serial numbers: 

There are 10 digits to Ducane serial numbers and there are two types of serial number. 

First type:

2246780515 (Made up serial number)

You will determine the month and the years from the last four digits of the serial number. 

224678|05|15 

05 is the year HVACs unit was made

22467805|15|

15 is the week HVACs unit was made. (15 weeks is in April)

This HVACs unit was made in April, 2005. 

Second Types: 

46 09E48972 (actual serial number)

To decode this serial number, you will only the first fifty serial numbers, including the letter E. (underline above)

46 is the plant location

09 is the year the HVACs unit made

E is the month the HVACs unit made

This HVACs unit was made in May, 2009

 

A = January
B = February
C = March
D = April
E = May
F = June
G = July
H = August
Letter “I” was skipped.
J = September
K = October
L = November
M = December

How to read and decode Ducane Model numbers:

What will we discuss? 

Ducane regular central ac unit, Heat Pump and package HVACs model number. 


Regular central air conditioner model number

Regular Ducane central air conditioner will start with the model number: 2AC13 B24P-2A or 4AC16 LT48P-1A (Made up model number)

2AC13B24P-2A = 

2 is Refrigerant R-22
AC is Split AC Unit
13 is SEER rating of that Ac unit
B is Wire Guard 

(notes- Instead of B, it has:

BC = Wire Guard + 76dBA
LC = Louvered + 76dBA
L = Louvered
B = Wire Guard

This is like the condenser model. Wire Guard is types of panel that protect the condenser coils. 

24 is Capacity or BTU. 24, 000 btu or 2 ton
P is Voltage. 208-230v/60hz
2 is Major Revision Code
A is Minor Revision Code

4AC16LT48P-1A =

4 is R410A refrigerant 
AC is Split Condenser Unit
16 is SEER rating of the unit
LT is Louvered Two Stage or it has L = Louvered
48 is Capacity. 48,000 btu = 4 ton
P is Voltage P-208-230v
1 is Major Revision Code
A is Minor Revision Code


Ducane Heat Pump Model Number
4HP16B24P-2A (Made up model number)

4 is R410a Refrigerant
HP is Heat Pump
16 is SEER rating of the Heat Pump
B is Wire Guard or it has:
L = Louvered
LT = Louvered Two Stage
24 is capacity. In BTU, Ton 
P is voltage. 208-230 V
2 is Major Revision Code
A is Minor Revision Code


Package HVACs Model Number
(Made up model number below)

 


R GE 14 A 48 072 L P – 1 A

R is Residential Packaged
GE is Gas/Electric
14 is SEER rating
A is Series
48 is Capacity
072 is Heating Btu, 72, 000 Btu
L is Low Nox. Nox (Blank Standard)
P is 208-230V
1 is Revision Code
A is A- Service Level


R CE 14 A 24 P - 1 A

R is Residential Packaged
CE is Electric/Electric
14 is SEER rating
A is Series
24 is Capacity. 24,000 BTU
P is 208-230 Voltage
1 is Revision Code
A is Service Level


4 SG 14 B 68 072 L P – 1 A

4 is R410a Refrigerant
SG is Package Gas/Electric
14 is SEER rating
B is Series
68 is Cooling Capacity. 68,000 Btu
072 is Heating Capacity. 72, 000 Btu
L is L – Low Nox. NOx (Blank –Standard)
P is 208-230 Voltage
1 is Major Revision Code
A is Minor Revision Code


2 SH 14 B 68 P – 1 A

2 is R-22 Refrigerant
SH is Package Heat Pump or it has:
SA = Single Package AC Unit
SG = Package Gas/Electric Unit
14 is SEER rating = 14 Seer Unit
B is Series
68 is Cooling Capacity 
P is 208-230 Voltage
1 is Major Revision Code
A is Minor Revision Code

我们的目标